Chapter 4 ParametersAutomatic Energy-saving OperationAutomatic Voltage Regulation (AVR)00: AVR function enabled01: AVR function disabled02: AVR function disabled for deceleration

Output voltage

100%

70%

 

 

 

 

During the auto energy-saving

 

 

 

 

operation, it will adjust the output

 

 

 

 

voltage according to the output

 

 

 

 

power. The maximum output

 

 

 

 

voltage can be 30% lower than

 

 

 

 

the normal output voltage.

 

 

 

 

Frequency

 

 

 

 

 

 

 

 

 

 

 

 

Automatic Energy-saving Operation

 

 

 

 

 

08 - 18

Automatic Voltage Regulation (AVR)

 

 

 

 

 

 

 

Factory Setting: 00

 

Settings

00: AVR function enabled

 

 

01: AVR function disabled

 

 

02: AVR function disabled for deceleration

 

 

 

 

 

 

 

 

This parameter determines the function of Automatic Voltage Regulation is enabled or disabled.

This parameter is set to 01: when AVR function is disabled, AC drive will calculate input voltage by DC Bus value (620VDC). Output voltage will vary by DC Bus varying and may cause output current insufficiently, over current or oscillation.

This parameter is set to 00: when AVR function is enabled, AC drive will calculate output voltage by actual voltage value of DC Bus. Output voltage won’t vary by DC Bus varying.

This parameter is set to 02: AC drive will disable AVR function during decelerate to stop. It can speed up braking in some degree.

 

08 - 19

Software Setting of the Braking Level

Unit: 0.1

 

(the action level of the braking resistor)

 

 

 

 

 

 

 

 

 

 

Settings

740.0V~820.0VDC

Factory Setting: 760.0

 

 

 

00: Disabled

 

 

 

 

 

 

This parameter determines software setting of the braking level.

The model VFD055~150F43A has braking chip, user could select suitable braking resistor to have the best deceleration characteristics.

The action level of the braking resistor could be set by this parameter.

Revision July 2008, EG03, SW V1.06

4-67