Chapter 4 Parameters

 

 

 

 

 

 

Group 5: Multi-step Speed Parameters

 

 

 

 

05 - 00

1st Step Speed Frequency

Unit: 0.01

05 - 01

2nd Step Speed Frequency

Unit: 0.01

 

 

 

05 - 02

3rd Step Speed Frequency

Unit: 0.01

05 - 03

4th Step Speed Frequency

Unit: 0.01

 

 

 

05 - 04

5th Step Speed Frequency

Unit: 0.01

05 - 05

6th Step Speed Frequency

Unit: 0.01

05 - 06

7th Step Speed Frequency

Unit: 0.01

05 - 07

8th Step Speed Frequency

Unit: 0.01

05 - 08

9th Step Speed Frequency

Unit: 0.01

05 - 09

10th Step Speed Frequency

Unit: 0.01

05 - 10

11th Step Speed Frequency

Unit: 0.01

05 - 11

12th Step Speed Frequency

Unit: 0.01

05 - 12

13th Step Speed Frequency

Unit: 0.01

05 - 13

14th Step Speed Frequency

Unit: 0.01

05 - 14

15th Step Speed Frequency

Unit: 0.01

 

Settings

0.00~160.00 Hz

Factory Setting: 0.00

 

 

 

 

 

The Multi-Function Input Terminals (refer to Pr.04-00 to 04-03) are used to select one of the AC drive Multi-Step speeds. The speeds (frequencies) are determined by Pr.05-00 to 05-14 shown above.

05 - 15 PLC Mode

 

 

Factory Setting: 00

Settings

00

Disable PLC operation

 

01

Execute one program cycle only

 

02

Continuously execute program cycles

 

03

Execute one program cycle only and step by step

 

04

Continuously execute program cycles step by step

 

 

 

This parameter selects the mode of PLC operation for the AC drive. The AC drive will change speeds and directions according to the user’s desired programming.

4-46

Revision July 2008, EG03, SW V1.06

Page 97
Image 97
Delta Electronics VFD-G manual Group 5 Multi-step Speed Parameters, 05 15 PLC Mode