Chapter 1 Introduction
1.1 Receiving and Inspection
This
Check to make sure that the package includes an AC motor drive, the User Manual/Quick Start and CD, dust covers and rubber bushings.
Inspect the unit to assure it was not damaged during shipment.
Make sure that the part number indicated on the nameplate corresponds with the part number of your order.
1.1.1 Nameplate Information
Example for 10HP/7.5kW
AC Drive Model
Input Spec.
Output Spec.
Output Frequency Range
Enclosure type
Bar Code
Serial Number
MODE | : | |
INPUT | : 3PH | |
OUTPUT | : 3PH |
Freq. Range : 0.1~120.00Hz
ENCLOSURE: TYPE 1
075F43AG4T5010001
1.1.2 Model Explanation
VFD 075 F 43
|
|
|
|
|
| |
|
|
|
|
|
| Version Type |
|
|
|
|
|
| |
|
|
|
|
|
| Input Voltage |
|
|
|
|
|
| |
|
|
|
|
|
| 43:Three phase 460V |
|
|
|
|
|
| |
Series |
|
|
|
|
| |
Name |
|
|
| Applicable motor capacity | ||
|
|
|
|
|
|
055:7.5HP(5.5kW) 075:10HP(7.5kW) 110:15HP(11kW)
150:20HP(15kW) 185:25HP(18.5kW) 220:30HP(22kW)
300:40HP(30kW) 370:50HP(37kW) 450:60HP(45kW)
550:75HP(55kW) 750:100HP(75kW) 900:125HP(90kW) 1100:150HP(110kW) 1320:175HP(132kW) 1600:215HP(160kW) 1850:250HP(185kW) 2200:300HP(220kW)
Revision July 2008, EG03, SW V1.06 |