Delta Electronics VFD-G manual B.2 Non-fuse Circuit Breaker Chart

Models: VFD-G

1 183
Download 183 pages 30.97 Kb
Page 167
Image 167
B.2 Non-fuse Circuit Breaker Chart

Appendix B AccessoriesManual background

B.2 Non-fuse Circuit Breaker Chart

The fuse should comply with UL248 and the breaker should comply with UL489. The current rating of the breaker shall be 2~4 times maximum output current rating. (Refer to Appendix A for rated input/output current)

 

3-phase

 

 

Model

Recommended non-fuse breaker (A)

 

 

VFD055F43B-G

30

 

 

VFD075F43B-G

40

 

 

VFD110F43A-G

50

 

 

VFD150F43A-G

60

 

 

VFD185F43A-G

75

 

 

VFD220F43A-G

100

 

 

VFD300F43A-G

125

 

 

VFD370F43A-G

150

 

 

VFD450F43A-G

175

VFD550F43A-G

250

 

 

VFD750F43A-G

300

 

 

VFD900F43C-G

300

 

 

VFD1100F43C-G

400

VFD1320F43A-G

500

 

 

VFD1600F43A-G

600

 

 

VFD1850F43A-G

600

 

 

VFD2200F43A-G

800

 

 