Chapter 4 Parameters




Group 10 PID Control Parameters
| Parameter | Functions | Settings | Factory | Customer |
|
| Setting |
| ||||
|
|
|
|
|
| |
Input Terminal for PID | 00: Disabled | 00 |
|
| ||
|
| Feedback | 01: Input via AI1 |
|
|
|
|
|
| 02: Input via AI2 |
|
|
|
|
|
| 03: Input via External Reference |
|
|
|
PID Control Detection | 1000.0 |
|
| |||
|
| Signal Reference |
|
|
|
|
PID Feedback Control | 00: Normal | 00 |
|
| ||
|
| Method | 01: Inverse |
|
|
|
Proportional Gain (P) | 0.0~10.0 | 1.0 |
|
| ||
Integral Time (I) | 0.00~100.00 Sec | 1.00 |
|
| ||
Differential Time (D) | 0.00~1.00 Sec | 0.00 |
|
| ||
Upper Bound for | 00~200% | 100 |
|
| ||
|
| Integral Control |
|
|
|
|
Primary Low Pass | 0.0~2.5 Sec | 0.0 |
|
| ||
|
| Filter Time |
|
|
|
|
PID Feedback Signal | 0.01 to | 600.0 |
|
| ||
|
| Range |
|
|
|
|
PID Feedback Signal | 0. 0~3600.0 Sec | 0.0 |
|
| ||
|
| Fault Treatment Time | 0.0: Disabled |
|
|
|
PID Feedback Signal | 00: Warn and RAMP stop | 01 |
|
| ||
|
| Fault Treatment | 01: Warn and COAST stop |
|
|
|
|
|
| 02: Warn and keep operating |
|
|
|
V/F Curve Selection | 00: Determined by group 01 | 00 |
|
| ||
|
|
| 01: 1.5 power curve |
|
|
|
|
|
| 02: 1.7 power curve |
|
|
|
|
|
| 03: 2 power curve |
|
|
|
|
|
| 04: 3 power curve |
|
|
|
Revision July 2008, EG03, SW V1.06 |