Chapter 4 Parameters
| Setting | Functions | Descriptions | ||
18 | PID disabled | Disable PID feedback control and operate via Master | |||
|
|
| Frequency Command source | ||
19 | Run PLC Program | Parameter value 32 programs | |||
|
|
| Terminal to enable the AC drive internal PLC program. | ||
20 | Pause PLC Program | ||||
Parameter value 33 programs an input terminal to pause | |||||
|
|
| |||
|
|
| the PLC program. |
| |
|
|
| Note: | ||
21 | 1st Output Frequency | Output frequency multiplies a gain | |||
|
| Gain |
| ||
22 | 2nd Output Frequency | Output frequency multiplies a gain | |||
|
| Gain |
| ||
23 | 3rd Output Frequency | Output frequency multiplies a gain | |||
|
| Gain |
|
04 - 04 Digital Input Terminal Response Time
Settings 01~20Factory Setting: 01
This parameter selects the response time of digital input terminals MI1 to MI4, EF and FWD. AC drive will scan the digital input terminals once every 2msec. During each scan the drive will check the status of each terminal (open or closed).
In noisy environments, it would be advantageous to verify the terminal status several times before executing a new command, nearly eliminating false signals.
Example: If
It is not recommended to set this parameter to 00, since interference may cause improper operation of the AC drive.
| 04 - 05 |
| Minimum AI1 Analog Input | Unit: 1 | |
|
|
| Settings | 0 ~ 100% | Factory Setting: 0 |
04 - 06 |
| Maximum AI1 Analog Input | Unit: 1 | ||
|
|
| Settings | 0 ~ 100% | Factory Setting: 100 |
|
|
|
| ||
|
|
|
| ||
| 04 - 07 |
| Minimum Output that corresponds to AI1 | Unit: 0.01 | |
|
|
| Settings | 0.00~100.00% | Factory Setting: 0.00 |
|
|
|
| ||
| 04 - 08 |
| Maximum Output that corresponds to AI1 | Unit: 0.01 | |
|
|
| Settings | 0.00~100.00% | Factory Setting: 100.00 |
|
|
|
|
|
|
Revision July 2008, EG03, SW V1.06 |