Chapter 4 Parameters

 

 

 

 

 

 

05 - 17

Time Duration of 1st Step Speed

Unit: 1 /0.1sec

05 - 18

Time Duration of 2nd Step Speed

Unit: 1 /0.1sec

 

 

 

05 - 19

Time Duration of 3rd Step Speed

Unit: 1 /0.1sec

 

 

 

05 - 10

Time Duration of 4th Step Speed

Unit: 1 /0.1sec

 

 

 

05 - 21

Time Duration of 5th Step Speed

Unit: 1 /0.1sec

 

 

 

05 - 22

Time Duration of 6th Step Speed

Unit: 1 /0.1sec

05 - 23

Time Duration of 7th Step Speed

Unit: 1 /0.1sec

 

 

 

05 - 24

Time Duration of 8th Step Speed

Unit: 1 /0.1sec

 

 

 

05 - 25

Time Duration of 9th Step Speed

Unit: 1 /0.1sec

 

 

 

05 - 26

Time Duration of 10th Step Speed

Unit: 1 /0.1sec

 

 

 

05 - 27

Time Duration of 11th Step Speed

Unit: 1 /0.1sec

05 - 28

Time Duration of 12th Step Speed

Unit: 1 /0.1sec

05 - 29

Time Duration of 13th Step Speed

Unit: 1 /0.1sec

05 - 30

Time Duration of 14th Step Speed

Unit: 1 /0.1sec

05 - 31

Time Duration of 15th Step Speed

Unit: 1 /0.1sec

 

Settings

0.0~65500 Sec / 0.0~6550.0 Sec

Factory Setting: 0.0

 

 

 

 

 

Pr.05-17 to Pr.05-31 correspond to operation time of each step speed defined by Pr.05-00 to Pr.05-14. The maximum setting 65500 seconds will be displayed as t6550. If it is displayed t6550. that means 6550 seconds.

Note: If a parameter is set to “00” (0 sec), the corresponding step will be skipped. This is commonly used to reduce the number of program steps.

4-50

Revision July 2008, EG03, SW V1.06

Page 101