Chapter 4 Parameters
09 - 05 Even/Odd Parity and Stopping Parity Setting
Factory Setting: 00
Settings | 00: None parity + 2 stop bit |
| 01: Even parity + 2 stop bit |
| 02: Odd parity + 2 stop bit |
| 03: None parity + 1 stop bit |
| 04: Even parity + 1 stop bit |
| 05: Odd parity + 1 stop bit |
|
|
This parameter determines the communication format of serial communication.
09 - 06 Communication Operation Command 1
Factory Setting: 00
Settings | Bit0~1: 00: Disabled |
| 01: Stop |
| 10: |
| 11: JOG |
| Bit2~3: Reserved |
| Bit4~5: 00: Disabled |
| 01: FWD command |
| 10: REV command |
| 11: Direction change command |
| Bit6~7: 00: 1st step acce/decel speed |
| 01: 2nd step acce/decel speed |
| 10: 3rd step acce/decel speed |
| 11: 4th step acce/decel speed |
| Bit8~11: 0000: Master speed |
| 0001: 1st step speed |
| 0010: 2nd step speed |
| 0011: 3rd step speed |
| 0100: 4th step speed |
| 0101: 5th step speed |
| 0110: 6th step speed |
| 0111: 7th step speed |
| 1000: 8th step speed |
| 1001: 9th step speed |
| 1010: 10th step speed |
| 1011: 11th step speed |
| 1100: 12th step speed |
| 1101: 13th step speed |
| 1110: 14th step speed |
| 1111: 15th step speed |
| Bit12: Select Bit6~11 function |
| Bit13~15: Reserved |
Revision July 2008, EG03, SW V1.06 |