TM-L90/TM-L90 with Peeler Technical Reference Guide
❏Interface Reset Signal
Pins #25 and #6 of the serial interface board unit
Press FEED button | Setting to select |
|
|
|
|
|
|
| Parallel interface #31 pin | Serial interface #25 pin | Serial interface #6 pin |
|
|
|
|
0 times: | No change |
|
|
|
|
|
|
1 time: | Enable | Disable | Disable |
|
|
|
|
2 times: |
|
| Enable |
|
|
|
|
3 times: |
| Enable | Disable |
|
|
|
|
4 times: |
|
| Enable |
|
|
|
|
5 times: | Disable | Disable | Disable |
|
|
|
|
6 times: |
|
| Enable |
|
|
|
|
7 times: |
| Enable | Disable |
|
|
|
|
8 times: |
|
| Enable |
|
|
|
|
9 or more times: | No change |
|
|
|
|
|
|
❏Selection of Paper width
Select Paper width by pressing the FEED button the number of times required.
Press FEED button | Paper width |
|
|
0 times: | No change |
|
|
1 time: | 38mm |
|
|
2 times: | 58mm |
|
|
3 times: | 60mm |
|
|
4 times: | 70mm |
|
|
5 times: | 80mm |
|
|
6 or more times: | No change |
|
|
Note:
When using label roll paper that can't be selected in the memory switch setting mode within the range from 38 mm to 80 mm, configure the paper width using any one of 3 control systems: OPOS, Advanced Printer Driver, or ESC/POS. The brief introduction of the control systems is in “Introduction of Control Methods” on page