RESTRICTED USE ONLY

Fargo Electronics, Inc.

Replacing the Ribbon ID Sensor Board Assembly (763173-2)

Caution: This device is electrostatic sensitive. It may be damaged if exposed to static electrical discharges. (Discharges may be generated by various means, such as walking on a carpeted floor.) Be sure to observe all established Electro-Static Discharge (ESD) procedures while handling cables in or near the Circuit Board and Printhead Assemblies. Always wear an appropriate personal grounding device, such as a wrist strap with integral resistor, connected to an ESD ground to avoid potential damage. At a minimum, make positive contact with the bare metal chassis of the printer with the hand before proceeding with the procedure.

Refer To Drawing 830117-XX. TTR: 15 minutes

Step

Procedure

 

 

1

Unplug the power cord from the printer.

 

 

2

Take the Front Cover off.

 

 

3

Remove the Retaining Ring (140009). Use a replacement Retaining Ring when

 

installing the new Ribbon ID Sensor Board Assembly.

 

 

4

Extract the Right Ribbon Hub (763345) and the Clutch Spacer (760386) off of

 

the Hub Linkage Assembly (810115).

 

 

5

Move the Ribbon ID Sensor Board Assembly off of the Hub Linkage Assembly.

 

Take care not to misplace the Spring; it can remain on the Hub Linkage

 

Assembly.

 

 

6

Disconnect the cable connection from J10 on the Print Circuit Board. See

 

Drawing 763173-X for specifications.

 

 

7

Tie a string to the cable connector and draw the string through the wire path.

 

Use the string as a means of routing the the new Ribbon ID Sensor Board

 

Assembly cable through the printer chassis.

 

 

8

Take the Ribbon ID Sensor Board ASsembly from the printer.

 

 