RESTRICTED USE ONLY

Fargo Electronics, Inc.

Replacing the Card Feed Switch Assembly (830136)

Refer To Drawing 830131, Item 12.

TTR: NA

In the unlikely event of failure, this cable is not field serviceable. Please contact the FARGO Technical Support Group at (952) 941-0050 for assistance.

Replacing the LED Board Assembly (830133)

Caution: This device is electrostatic sensitive. It may be damaged if exposed to static electrical discharges. (Discharges may be generated by various means, such as walking on a carpeted floor.) Be sure to observe all established Electro-Static Discharge (ESD) procedures while handling cables in or near the Circuit Board and Printhead Assemblies. Always wear an appropriate personal grounding device, such as a wrist strap with integral resistor, connected to an ESD ground to avoid potential damage. At a minimum, make positive contact with the bare metal chassis of the printer with the hand before proceeding with the procedure.

Sub-assembly of 830126, Item 13. Refer To Drawing 830118-XX. TTR: 15 minutes

Step

Procedure

 

 

1

Unplug the power cord from the printer.

 

 

2

Take off the Rear Pivot Cover.

 

 

3

Detach the Print Circuit Board from the chassis. Do not remove any wire

 

connectors unless indicated.

 

 

4

Remove the Screw (130971) that holds the Lower Ribbon Sensor Assembly to

 

the Rear Side Plate. Refer to Drawing 830126.

 

 

5

Disconnect the cable connector from J12, pins 1and 2 on the Print Circuit

 

Board.

 

 

6

Remove the LED Board Assembly from the Bottom Sensor Bracket and the

 

printer. See Drawing 830133 for specifications.

 

 

Persona C10/M10 ID Card Printer Service Manual (Rev. 4.0)

134

 

Page 134
Image 134
FARGO electronic M10, C10 service manual Replacing the Card Feed Switch Assembly, Replacing the LED Board Assembly