4 - 116

COMMAND REFERENCE

Description:

The TRIGger:FILTer:HPASs:FREQuency command sets the MTB cutoff frequency always at the fixed value of 30000 Hz (all values are rounded to 30 KHz).

The TRIGger:FILTer:HPASs:STATe command activates (ON) or deactivates (OFF) the MTB high-pass filter.

Activating the MTB high-pass filter:

-automatically deactivates the MTB low-pass filter.

-sets the high-pass cutoff frequency at 30 KHz (HF-reject).

-sets the low-pass cutoff frequency at 0 Hz.

DeActivating the MTB low-pass filter:

-automatically activates the MTB low-pass filter.

-sets the high-pass cutoff frequency at bandwidth (60/100/200 MHz).

-sets the low-pass cutoff frequency at 0 Hz (DC coupling).

After a *RST command, the high-pass filter is OFF.

Note: The following coupling exists between programming the cutoff frequency and (de)-activating the low-pass or high-pass filter:

 

 

 

 

FILTER

 

 

FREQUENCY

LOW-PASS ON

 

HIGH-PASS ON

 

 

 

 

 

 

 

 

 

 

 

0

Hz

DC coupling

 

HF-reject

 

10

Hz

AC coupling

 

HF-reject

 

30

KHz

LF-reject

 

HF-reject

 

Example:

 

 

 

 

 

Send TRIGger:FILTer:HPASs:STATe ON

 

Sets High-Pass filter on

 

 

 

 

 

(HF-reject).

 

 

 

 

 

Automatically switches

 

 

 

 

 

Low-Pass filter off.

Front panel compliance:

The TRIGger:FILTer:HPASs commands are the remote equivalent of the front panel TRIGGER MAIN TB - ac, dc, lf-rej, hf-rej softkey menu.

Page 216
Image 216
Fluke PM-3390B, PM-3380B Filter Frequency LOW-PASS on HIGH-PASS on, DC coupling HF-reject AC coupling KHz LF-reject