B - 28

CROSS REFERENCES

FUNCTION + KEYS/MENUS

RELATED SCPI COMMAND(S)

 

 

VOLT MEASUREMENTS

 

key MEASURE

SYSTem:KEY 110

menu MEASURE

DISPlay:MENU MEASure

- softkeys n = 1 .. 6

SYSTem:KEY n

- MEAS 1 & MEAS 2

DISPlay:WINDow[1]:TEXT<12>:DATA?

-

dc voltage

MEASure[:DC]?

-

rms voltage

MEASure:AC?

-

amplitude voltage

MEASure:AMPLitude?

-

max voltage

MEASure:MAXimum?

-

min voltage

MEASure:MINimum?

-

peak-to-peak voltage

MEASure:PTPeak?

-

high level voltage

MEASure:HIGH?

-

low level voltage

MEASure:LOW?

-

falling overshoot voltage

MEASure:FALL:OVERshoot?

-

falling preshoot voltage

MEASure:FALL:PREShoot?

-

rising overshoot voltage

MEASure:RISE:OVERshoot?

-

rising preshoot voltage

MEASure:RISE:PREShoot?

Note: MEASure? can be substituted by CONFigure + READ? or by CONFigure + INITiate + FETCh?

X-DEFLECTION (X-DEFL, X vs Y)

 

key DISPLAY

SYSTem:KEY 209

menu DISPLAY

DISPlay:MENU DISPlay

- softkeys n = 1 .. 6

SYSTem:KEY n

 

 

Notes: The functions, keys, menus, and related SCPI commands for the PM33x0B CombiScope instruments are:

-not applicable for channel 3.

-partly available for channel 4 as external trigger input.

Page 273
Image 273
Fluke PM-3394B, PM-3380B, PM-3390B, PM-3370B, PM-3384B user manual DISPlayWINDow1TEXT12DATA?