Fluke PM-3390B, PM-3380B, PM-3370B, PM-3394B, PM-3384B user manual DISPlayMENUNAME

Models: PM-3394B PM-3390B PM-3370B PM-3380B PM-3384B

1 297
Download 297 pages 56.64 Kb
Page 146
Image 146

4 - 46

COMMAND REFERENCE

DISPlay:MENU[:NAME]

Syntax: DISPlay:MENU[:NAME] <character_data>

<character_data>

FRONT PANEL SOFTKEY NAME

TBMode

TB MODE

(main time base)

TRIGger

TRIGGER

 

DMODe

DTB

(delayed time base)

SETups

SETUPS

 

CURSors

CURSORS

 

ACQuire

ACQUIRE

 

DISPlay

DISPLAY

 

MATH

MATH

 

MEASure

MEASURE

 

SAVE

SAVE

 

RECall

RECALL

 

UTIL

UTILITY

 

VERTical

VERT MENU

 

Description:

The DISPlay:MENU command can be used to select a softkey menu by specifying a predefined name. Additionally, the display of the softkey menu field is switched ON. So, the execution of the DISPlay:MENU command is coupled to the execution of the DISPlay:MENU:STATe ON command. The menus ACQuire, DISPlay, MATH, MEASure, SAVE, and RECall are available in the digital mode. If they are specified in the analog mode, error -221 "Settings conflict;Digital mode required" is generated.

After a *RST command, the mode is set at TBMode without display of the TB MODE softkey menu field.

Example:

Send DISPlay:MENU TBMode Selects and displays the TB MODE softkey

menu.

Front panel compliance:

The DISPlay:MENU command is the remote equivalent of the front panel menu buttons TB MODE, TRIGGER, DTB, SETUPS, CURSORS, ACQUIRE, DISPLAY, MATH, MEASURE, SAVE, RECALL, UTILITY, and VERT MENU.