CROSS REFERENCES

B - 1

APPENDIX B CROSS REFERENCES

B.1 Cross Reference Front Panel Keys / Commands

The front panel picture is copied from the operation guide, showing the SCPI commands corresponding to front panel keys.

 

SENS:SWE:OFFS:TIME

 

 

 

 

 

TRIG:HOLD

 

 

 

 

CAL?

 

 

INST DIG

 

 

 

 

 

 

INIT:CONT

 

 

 

 

CAL

 

 

 

ANAL

 

 

 

 

 

 

 

 

 

 

 

 

AUTO SET CAL

SETUPS UTILITY

 

 

ANOLOG

ACQUIR: SAVE_RECALL MEASURE MATH DISPLAY HARD COPY

 

CONF:AC (@n)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HCOP:DATA?

 

STATUS

 

 

 

CURSORS

 

 

 

 

 

TRIGGER

MAGNIFY

X POS

 

 

 

TRACK

 

 

 

HOLD OFF

 

 

 

 

 

 

 

LOCAL

 

 

 

 

 

 

 

 

 

 

 

AUTO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RUN/STOP RANGE

SINGLE_ARM'D

 

INIT

1

 

 

 

 

 

 

 

 

 

TRIGGER

 

 

 

TRIGGER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DELAYED TIME BASE

 

DELAY

 

POSITION

 

TIME/DIV

LEVEL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

DTB

 

s TIME/DIV ns

 

 

 

 

 

TB MODE

s VAR ns

 

 

TRIG:LEV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

1

 

 

 

VERT MENU

2

 

 

 

AVERAGE

 

 

 

 

 

 

SENS:SWE:TIME

 

 

 

 

 

 

 

 

 

 

 

 

4

POS

 

POS

 

 

3POS

 

 

4POS

 

SENS:SWE:TIME:AUTO

 

 

 

 

TRIG1

 

 

 

 

TRIG2

 

 

TRIG3

 

 

TRIG4

5

 

 

 

AUTO

 

 

AUTO

 

AUTO

 

 

AUTO

 

 

 

AMPL

 

RANGECH1+CH2

AMPL

RANGE

INV

AMPL RANGE CH3+CH4

AMPL

RANGE

INV

 

6

 

 

mV

 

 

 

mV

 

 

mV

 

 

mV

 

INP4:POL

 

 

 

 

 

 

 

 

 

 

 

 

 

TEXT OFF

 

VAR

ON

AC DC

 

 

VAR

ON

AC DC

VAR

ON

AC DC

VAR

ON

AC DC

 

 

 

 

GND

 

 

GND

GND

GND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V

 

 

 

 

V

 

 

V

 

 

V

 

 

 

SENS:VOLT1:RANG:OFFS

 

 

 

 

 

 

 

 

 

 

INP2:POL

 

 

 

 

SENS:VOLT1:RANG:PTP

 

 

 

 

SENS:AVER

Any softkey menu:

 

 

 

 

ON

 

 

 

 

 

 

 

 

DISP:MENU menu_name

 

 

 

 

 

 

 

 

 

 

SENS:FUNC: OFF

"XTIM:VOLT1"

 

 

 

Softkey 1 .... 6:

 

STAT

 

 

 

 

 

 

 

ALSO FOR

 

 

 

 

 

 

 

 

 

SYST:KEY 1 .... 6

SENS:VOLT1:RANG:AUTO

 

 

 

 

 

 

CHANNEL 2, 3, AND 4

 

 

 

 

 

 

 

 

 

AC

 

 

 

 

 

 

 

 

TRACE INTENSITY:

 

 

 

 

 

 

 

 

 

 

INP1:COUP

DC

 

 

 

 

 

 

 

 

DISP:BRIG

 

 

 

 

 

 

 

 

 

GRO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

ST7431

SENS:FUNC: OFF

"XTIM:VOLT:SUM 1,2"

 

 

 

 

 

 

 

 

 

 

 

STAT

 

 

 

 

 

 

 

 

 

TRIG:SOUR

INT1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TRIG:SLOP

POS

 

 

 

 

 

 

 

 

 

 

NEG

 

 

 

 

 

 

 

 

 

Notes: - Channel 3 is not applicable for PM33x0B.

-Channel 4 is external trigger input for PM33x0B.

Page 246
Image 246
Fluke PM-3390B, PM-3380B, PM-3370B, PM-3394B, PM-3384B Cross Reference Front Panel Keys / Commands, Cross References