3.11.2.2Display of user-defined text

The DISPlay:WINDow2:TEXT commands allow you to define and clear the user text on the screen area of your CombiScope instrument. After a *RST command, the display of the previously defined user text is turned off.

PROGRAM EXAMPLE 1: (text as string data)

CALL Send(0, 8, "DISPlay:WINDow2:TEXT:STATe ON", 1) ’Enables display of text

CALL Send(0, 8, "DISPlay:WINDow2:TEXT:DATA ’Remote control’", 1)

Displays the text: Remote control on the screen of your CombiScope instrument.

PROGRAM EXAMPLE 2: (text as block data)

CALL Send(0, 8, "DISPlay:WINDow2:TEXT:CLEar", 1) ’Clears the text CALL Send(0, 8, "DISPlay:WINDow2:TEXT:DATA #01.25 k", 0)’Displays: 1.25 k

CALL Send(0, 8, CHR$(25), 0)

Displays: Ω

CALL Send(0, 8, " CH1", 1)

Displays: CH1

 

Displays the text: 1.25 kW CH1 on the screen of your CombiScope instrument.

 

Note: The ASCII character 25 (= ) is displayed as Ω on the screen of your CombiScope instrument.

3.11.2.3Selection of softkey menus

The DISPlay:MENU commands allow you to select and enable the display of a softkey menu. If a menu is selected via the DISPlay:MENU command, the display is automatically enabled. After a *RST command, the display of softkey menus is turned off.

PROGRAM EXAMPLE:

CALL Send(0,

8,

"DISPlay:MENU CURSors", 1)

Selects and displays the

 

 

 

CURSORS menu.

CALL Send(0,

8,

"DISPlay:MENU:STATe OFF", 1)

Switches the CURSORS menu

 

 

 

display off.