5016-001

 

FRU

Action

 

 

 

2

Interlock Switch

Switch S2 has two functions. Two terminals control

 

S2

+24 V dc to the engine board and four terminals

 

 

control the AC line voltage to the fuser lamps.

 

 

Terminal A3 (red wires) and terminal B3 (blue

 

 

wires) control the +24 V dc supply to the engine

 

 

board. When this circuit opens, a Close Door

 

 

message displays.

 

 

CAUTION: Be careful when checking the voltages

 

 

on switch S2, as the AC line voltage may be

 

 

present on terminals A1 (brown), B1 (yellow), A2

 

 

(brown) or B2 (yellow).

 

 

Check the voltage at terminal B3 (blue wires). It

 

 

should read approximately +24 V dc.

 

 

If incorrect, go to the “Printhead Service

 

 

 

Check” on page 2-77.

 

 

If correct, check the voltage on switch terminal

 

 

 

A3 (red wires).

 

 

 

• If incorrect, check the switch for continuity

 

 

 

and proper operation.

 

 

 

• If correct, check the cable from the wires.

 

 

 

• If incorrect, check the switch for continuity

 

 

 

and proper operation.

 

 

 

• If correct, check the cable from the switch

 

 

 

to the engine board.

 

 

 

• If incorrect, replace the cable.

 

 

 

• If correct, replace the engine board.

 

 

 

 

2-46Service Manual

Page 112
Image 112
Lexmark 5016-001 manual If correct, check the voltage on switch terminal