5016-001

B 990 Service Engine Error - Motor turns.

Note: Observe the coupling operation as the printer is performing the self test and the engine is warming up. Determine when the failure occurs.

 

FRU

Action

 

 

 

1

Motor Mounting

Check the parts associated with the coupling

 

Stay A

operation for signs of excessive wear, breakage or

 

Assembly

looseness. Check the coupling arm, coupling shaft

 

Coupling parts

and cam.

 

• If a problem exists, repair or replace the

 

 

 

 

complete motor mounting stay A assembly.

 

 

• If no problem is found with the stay A assembly,

 

 

check the detent arm, detent spring, coupling

 

 

arm and coupling shaft for signs of binding,

 

 

wear, breakage or looseness. Repair as

 

 

necessary.

 

 

 

Diagnostic Information 2-43

Page 109
Image 109
Lexmark 5016-001 manual Service Engine Error Motor turns