5016-001

Fuser Cold Service Check

922 Error - Fuser below maintenance count.

Note: If selected, turn Power Saver off.

Error codes 920, 921 and 922 may display for a cold fuser failure. A 920 fuser error caused by low line voltage may be cleared by turning the printer on and off.

 

FRU

Action

 

 

 

1

Fuser Assembly

Be sure the fuser assembly is correctly installed

 

Fuser Lamp

and locked down. Disconnect the AC power

 

cord from the printer. Disconnect CN406 from

 

Circuit

the LVPS board and check for continuity

 

 

between pins 1 and 2 on the CN406 cable

 

 

connector.

 

 

If incorrect, go to step 2.

 

 

• If correct, check the voltage between CN406

 

 

 

Pin 1 and 2. The voltage should read the

 

 

 

same as the AC line voltage.

 

 

 

• If incorrect replace the LVPS.

 

 

 

2

Fuser Lamp

Remove the fuser assembly from the printer.

 

Thermostat

Note: Take care not to damage any pins when

 

Fuser Lamp

checking continuity.

 

 

 

 

Contacts

Check continuity between the two outer fuser

 

 

lamp contacts of the autoconnector (HCU cable)

 

 

located on the bottom of the fuser assembly.

 

 

If correct, go to step 3.

 

 

If incorrect, check the fuser lamp, thermostat,

 

 

 

fuser lamp contacts and HCU cable, replacing

 

 

 

any defective parts.

 

 

 

3

Interlock Switches

Go to the “Cover Interlock Service Check” on

 

 

page 2-45.

 

 

 

 