5016-001

Main Fan Service Check

 

FRU

Action

 

 

 

1

Main Fan Cable

Be sure the fan cable in-line connector is

 

 

connected properly to the CRF cable from the

 

 

engine board.

 

 

 

2

Main Fan

Manually spin the fan and verify it rotates freely.

 

Engine Board

 

 

Cable (CRF)

• If incorrect, replace the engine board (CRF)

 

Engine Board

to fan cable.

 

 

• If the fan turns freely, turn the printer off and

 

 

check the voltages below from the fan

 

 

connector to the printer board cable (CRF),

 

 

as you turn the printer on.

Fan cable connector:

Pin 1 (Green)

0 V dc (running and not running)

Pin 2 (Yellow)

0 V dc (fan not running) +5 V dc (fan running)

Pin 3 (Red)

0 V dc (fan not running) +24 V dc (fan running)

If any of the voltages are incorrect, disconnect the fan cable from the engine board cable and check the voltages on the engine board cable connector.

If correct, replace the main fan.

If incorrect, check the engine board cable (CRF).

If incorrect, replace the cable.

If correct, replace the engine board.

2-62Service Manual