G POR incomplete. Close door message displays when duplex option installed and all doors and covers on the duplex are closed.

 

FRU

Action

 

 

 

 

 

 

1

Tray Present

Check the voltages on the duplex tray detect

 

Detect Sensor

sensor on connector CN905.

 

 

(S9)

Pin #

Voltage

Voltage

Voltage

 

 

 

Duplex Option

5 (Red)

Signal

Closed

Open

 

Controller Board

VL

+5 V dc

+5 V dc

 

6 (Blue)

POSN

+5 V dc

0 V dc

 

 

 

 

7 (Green)

DGND

0 V dc

0 V dc

 

 

All voltages are approximate values.

 

 

If the voltage on pin 5 is incorrect, replace the

 

 

 

duplex option controller board.

 

 

If the voltage on pin 6 does not change when

 

 

 

the duplex tray is open and closed, replace the

 

 

 

FRUs in the following order:

 

 

 

1.

Tray detect sensor (DRSN)

 

 

 

2.

Duplex option controller board

 

 

 

2

Duplex Upper

Check the voltages on the duplex upper unit door

 

Unit Door Open

open sensor on connector CN904.

 

Sensor(S6)

Pin #

Voltage

Voltage

Voltage

 

 

 

Duplex Option

14

 

Signal

Closed

Open

 

Controller Board

 

VL

+5V dc

+5V dc

 

16 (yellow)

DOSN

+5 V dc

0 V dc

 

 

 

 

18

 

DGND

0 V dc

0 V dc

 

 

All voltages are approximate values.

 

 

If the voltage on pin 14 is incorrect, replace the

 

 

 

duplex option controller board.

 

 

If the voltage on pin 16 does not change when

 

 

 

the upper unit cover is opened and closed,

 

 

 

replace the FRUs in the following order:

 

 

1.

Duplex upper unit door open sensor

 

 

2.

Duplex option controller board

 

 

 

 

 

 

 

2-126Service Manual