5016-001

 

FRU

Action

 

 

 

 

5

LVPS Fuses

Check the AC line voltage on the LVPS at

 

F401, F402

connectors CN404 and CN405.

 

either or both

If incorrect, go to step 6.

 

continue to blow

If correct, disconnect the cables to CN401,

 

after being

 

 

CN402 and CN403.

 

replaced.

 

 

 

 

 

 

(Continued)

Check the voltage at CN401 pin 1 or 2. The

 

 

voltage should measure approximately +5 V dc.

 

 

If incorrect, replace the LVPS.

 

 

• If correct, reconnect the cable to CN401 and

 

 

 

recheck the voltage. If incorrect, go to step 6.

 

 

 

• If correct, reconnect the cable to CN402

 

 

 

and recheck the voltage. If incorrect, go to

 

 

 

step 7.

 

 

 

 

• If correct, reconnect the cable to CN403

 

 

 

and recheck the voltage. If incorrect, go to

 

 

 

step 8.

 

 

 

 

CN401

 

 

 

 

Pin 1, Pin 2 Approximately +5 V dc

 

 

 

Pin 3, Pin 4

Ground

 

 

 

Pin 5

Fuser On

 

 

 

CN402

 

 

 

 

Pin 1, Pin 2 Approximately +5 V dc

 

 

 

Pin 3, Pin 4

Ground

 

 

 

6

LVPS Fuses

The problem might be with the following:

 

F401, F402

Interconnect board.

 

either or both

 

Any option installed on the interconnect

 

continue to blow

 

 

board.

 

 

after being

 

 

 

Controller board.

 

replaced.

 

• COS.

 

 

(Continued)

 

 

 

• Memory DIMM installed on the controller

 

 

 

board.

 

 

 

Remove and replace one FRU at a time until

 

 

you find the failing component.

 

 

 

7

LVPS Fuses

The problem might be with the following:

 

F401, F402

• Engine board

 

 

either or both

 

 

• Any sensor or motor connected to the engine

 

continue to blow

 

 

board.

 

 

after being

 

 

 

 

 

 

 

replaced.

Remove and replace one FRU at a time until

 

(Continued)

you find the failing component.

 

 

 

 

 

2-74Service Manual

Page 140
Image 140
Lexmark 5016-001 manual CN401