5016-001

 

 

FRU

Action

 

 

 

 

 

 

2

 

S3, S4 Interlock

Check the cable from the interlock microswitch S3

 

 

Switch Cables.

Pin 1 (orange lead) to connector CNLS2 on the

 

 

Printhead to

printhead and the yellow jumper from S3 Pin 2 to

 

 

Engine Board

S4 Pin 2. Be sure these cables are connected

 

 

Cable

properly and are not damaged. Be sure to note the

 

 

 

interlock switch cable connector mounted to the

 

 

 

left side frame.

 

 

 

 

If a problem is found with any of these cables,

 

 

 

replace the failing cable.

 

 

 

 

Check the printhead to engine board cable for

 

 

 

correct installation and damage.

 

 

 

If correct, check the continuity of the cable.

 

 

 

If incorrect, replace the cable and go to B.

 

 

 

 

 

 

 

B 934 and 935 Error Codes

 

 

 

 

 

 

 

 

 

 

FRU

Action

 

 

 

 

 

 

1

 

Engine Board to

Check the cable for damage and correct

 

 

Printhead Cable

installation. Check continuity of the cable. If not

 

 

 

correct, replace the cable.

 

 

 

 

 

 

2

 

Engine Board to

Check the following voltages:

 

 

 

Printhead

 

Engine board CN14

 

 

 

 

 

 

 

 

 

 

Pin #

Signal Voltage

Voltage

 

 

 

 

Pin 5

+24 V dc

+24 V dc

 

 

 

 

Pin 6

+5 V dc

+5 V dc

 

 

 

 

Pin 19

+5 V dc

+5 V dc

 

 

 

All voltages are approximate.

 

 

 

 

If any voltage is incorrect, replace the engine

 

 

 

 

board.

 

 

 

 

 

If voltages are correct, replace the printhead

 

 

 

 

first.

 

 

 

 

 

If this does not fix the problem, replace the

 

 

 

 

engine board.

 

 

 

 

 

 

 

 