Cover Interlock Service Check

Check that switches S2, S3, and S4 are open. These should be open anytime the cartridge, fuser or front covers are not latched properly.

When a cover is opened, switch S2 opens the +24 V dc supply to the engine board and the AC line from the LVPS to the fuser lamps. Switches S3 and S4 open the +5 V dc supply from the engine board to the printhead.

If Door Open displays, go to A.

If a 922 Fuser Error displays, go to B.

ADoor Open displayed.

 

FRU

Action

 

 

 

1

Interlock Switch

Check the interlock switch actuator hardware for

 

Mechanism

proper operation and be sure:

 

 

• Actuator 1 activates door switch S2.

 

 

• +5 V dc to interlock switches S3 and S4.

 

 

If the mechanism does not operate properly or

 

 

activate any of the switches, repair as necessary.

 

 

 