Chapter 4 Register Descriptions
© National Instruments Corporation 4-67 GPIB-1014 User Manual
Bit Mnemonic Description
1w LMR Local Master Reset Bit
The Local Master Reset bit is used to reset the GPIB-1014 to a known
state. Setting this bit to a 1 drives the local reset line active while
clearing this bit releases the local reset line. The local reset line must
be left in the active state for at least 10 msec to ensure that the onboard
circuitry is reset properly.
0 = Local reset line inactive
1 = Local reset line active
VMEbus signal SYSRESET*, if asserted, will automatically force a
Local Master Reset.
0w SC System Controller Bit
The System Controller bit is used to control whether the GPIB-1014 is
in the System Controller mode or not.
0 = GPIB-1014 is not System Controller
1 = GPIB-1014 is System Controller
This bit is cleared (not System Controller) upon reset or power-up.