Chapter 7 Diagnostic and Troubleshooting Test Procedures
© National Instruments Corporation 7-3 GPIB-1014 User Manual
105 CFG2 = 08 Clear LMR
065 NIV1 = 55
065 NIV1 = 55?
067 EIV1 = 55
067 EIV1 = 55?
105 CFG2 = 0A Set LMR and turn LED green
105 CFG2 = 08 Clear LMR
065 NIV1 = 0F?
067 EIV1 = 0F?
5. Test ton, DO, ERR, CPTR, TA.
105 CFG2 = 0A Set LMR and turn LED green
105 CFG2 = 08 Clear LMR
11B AUXMR = 2 TLC Reset
119 ADMR = 80 ton
11B AUXMR = 0 Immediate execute pon
119 ADSR = 42? TA
113 ISR1 = 2? DO
111 CDOR = 51 write data byte
11B CPTR = 51? verify
113 ISR1 = 6? DO + ERR
113 ISR1 = 0? bits cleared when read
11B AUXMR = 2 TLC Reset
119 ADMR = 0 disable ton
11B AUXMR = 0 Immediate execute pon
119 ADSR = 40? not TA
6. Check lon, LA.
105 CFG2 = 0A Set LMR and turn LED green
105 CFG2 = 08 Clear LMR
11B AUXMR = 2 TLC Reset
113 IMR1 = 0 no interrupts
115 IMR2 = 0 no interrupts
119 ADMR = 40 lon
11B AUXMR = 0 Immediate execute pon
119 ADSR = 44? LA
11B AUXMR = 2 TLC Reset
119 ADSR = 40? not LA
7. Test ATN, CIC, CO.
105 CFG2 = 0B Set LMR and turn LED green
105 CFG2 = 09 Clear LMR and become System Controller
11B AUXMR = 2 TLC Reset
119 ADMR = 31 Address Mode 1
11B AUXMR = 0 Immediate execute pon