Appendix C Sample Programs
© National Instruments Corporation C-7 GPIB-1014 User Manual
|
| * * * * * * * * * * * * * * * * * * * * * *
| * INTERFACE CLEAR - IFC *
| * * * * * * * * * * * * * * * * * * * * * *
|
| Summary:
| - Initialize the interface function of other GPIB
| devices
|
| Assumptions on entry:
| - GPIB-1014 has been initialized
| - GPIB-1014 is System Controller (SC is true)
|
| Actions:
| - Assert GPIB IFC
| - Wait at least 100 microseconds
| - Unassert IFC
|
| Status on return:
| - GPIB-1014 is Active Controller
| - Interface functions of other GPIB devices are reset
| to their idle states
|
68000 Code | Comments
--------------------------------------------------------------------------------------------------------------------------------------------
|
|
IFC: movb #SIFC,AUXMR | Set the IFC signal
|
movb #50,d1 | Wait at least 100 microseconds
IFC1: subb #1,d1 |
bne IFC1 |
|
movb #CIFC,AUXMR | Clear IFC
|
rts |