Diagnostic and Troubleshooting Test Procedures Chapter 7
GPIB-1014 User Manual 7-2 © National Instruments Corporation
2. Examine any read and write routines being used in connection with the checkout procedure
for errors.
3. Recheck the jumper settings described in Chapter 3.
After these items have been carefully checked, if the interface is still not functioning properly,
gather together the information concerning what the GPIB-1014 is and is not doing with regard
to the expected results and contact National Instruments.
GPIB-1014 Hardware Installation Tests1. Initialize TLC.
105 CFG2 = 0A Set LMR and turn the LED green
105 CFG2 = 08 Clear LMR
11B AUXMR = 2 TLC Reset
11B AUXMR = 0 Immediate execute pon
2. Send LMR, then read registers and compare to reset values.
105 CFG2 = 0A Set LMR and turn LED green
105 CFG2 = 08 Clear LMR
111 DIR = 0? (cleared?)
113 ISR1 = 0?
115 ISR2 = 0?
117 SPSR = 0?
119 ADSR = 40?
11B CPTR = 0? (cleared?)
0FF GCR = 0?
007 CCR0 = 0?
047 CCR1 = 0?
000 CSR0 = 01?
040 CSR1 = 01?
065 NIV1 = 0F?
067 EIV1 = 0F?
3. Test DMAC Channel Address Registers.
105 CFG2 = 0A Set LMR and turn LED green
105 CFG2 = 08 Clear LMR
00C MAR0 = 5533
00C MAR0 = 5533?
04C MAR1 = 5533
04C MAR1 = 5533?
01C BAR1 = 5533
01C BAR1 = 5533?
4. Test Local Master Reset.