Power over Ethernet (PoE) Commands
523
ProSafe Managed Switch
used to reset the PoE port. The command can also reset the power-delivering ports. Note that
this command takes effect only once after it is executed and cannot be saved across power
cycles.
poe timer schedule name
Use this command to allow you to attach a timer schedule to a PoE port.
You can define a time schedule using the existing time range commands. This schedule has start
and stop times. When this timer schedule is applied to a PoE-enabled port, the capability of the
port to deliver power is affected. At the scheduled start time, the PoE port is disabled such that it
cannot deliver any power. At the scheduled stop time, the PoE port is reenabled so that it can
deliver power.
Note: For information about creating a timer schedule, see Time Range
Commands for Time-Based ACLs on page 506.
Format poe reset
Mode Global Config
Interface Config
Format poe timer schedule <name>
Mode Interface Config