Utility Commands
627
ProSafe Managed Switch
rmon alarm
This command sets the RMON alarm entry in the RMON alarm MIB group.
Format rmon alarm alarm number variable sample interval sampling type
rising-threshold value falling-threshold value startup
rising/falling/rising-falling owner string
Mode
no rmon alarm
This command deletes the rmon alarm entry.
Format no rmon alarm <alarm number>
Mode
rmon hcalarm
This command sets the rmon hcalarm entry in the High Capacity RMON alarm mib group.
Format rmon hcalarm <alarm number> <variable> <sample interval>
<sampling type> rising-threshold high <value> low
<value> falling-threshold high <value> low <value>
startup <rising/falling/rising-falling> owner <string>
Mode
Global Config
Parameter Description
Alarm Number The Alarm number which identifies an Alarm.
Alarm Variable The object identifier of the particular variable to be sampled. Only variables that resolve to an
ASN.1 primitive type of integer.
Sample Interval The interval in seconds over which the data is sampled and compared with the rising and
falling thresholds. The range is 0 to 2147483647. The default is 0.
Alarm Sample Type The alarm sample type. The method of sampling the selected variable and calculating the
value to be compared against thresholds. Possible types are Absolute or Delta.
Alarm Rising
Threshold Value The alarm rising threshold for the sample statistics.
Alarm Falling
Threshold Value The alarm falling threshold for the sample statistics.
Alarm Startup
Alarm The alarm that may be sent. Possible values are Rising Alarm, Falling Alarm or both.
Alarm Owner string The alarm owner. The owner string associated with the alarm entry.
Global Config
Global Config