Log Messages
723
ProSafe Managed Switch
Table 5. System Log Messages
Component Message Cause
SYSTEM Configuration file Switch CLI.cfg size is 0
(zero) bytes The configuration file could not be read.
This message may occur on a system for
which no configuration has ever been
saved or for which configuration has been
erased.
SYSTEM could not separate
SYSAPI_CONFIG_FILENAME The configuration file could not be read.
This message may occur on a system for
which no configuration has ever been
saved or for which configuration has been
erased.
SYSTEM Building defaults for file <file name> version
<version num> Configuration did not exist or could not be
read for the specified feature or file.
Default configuration values will be used.
The file name and version are indicated.
SYSTEM File <filename>: same version (version
num) but the sizes (<version
size>-><expected version size) differ
The configuration file which was loaded
was of a different size than expected for the
version number. This message indicates
the configuration file needed to be migrated
to the version number appropriate for the
code image. This message may appear
after upgrading the code image to a more
current release.
SYSTEM Migrating config file <filename> from
version <version num> to <version num> The configuration file identified was
migrated from a previous version number.
Both the old and new version number are
specified. This message may appear after
upgrading the code image to a more
current release.
SYSTEM Building Defaults Configuration did not exist or could not be
read for the specified feature. Default
configuration values will be used.
SYSTEM sysapiCfgFileGet failed size = <expected
size of file> version = <expected version> Configuration did not exist or could not be
read for the specified feature. This
message is usually followed by a message
indicating that default configuration values
will be used.