Using the Console Interface

 

 

 

Table 3-4 describes the System Characteristics screen fields.

Table 3-4.

System Characteristics Screen Fields

 

 

 

Field

Description

 

 

 

MAC Address

The MAC address of the BayStack 350 switch.

Reset Count

A read-only field that indicates the number of resets since the operational firmware

 

was first loaded on the switch.

 

Default Value:

1

 

Range:

0 to 232 -1

Last Reset Type

A read-only field that indicates the last type of reset.

 

Default Value:

Power Cycle

 

Range:

Power Cycle, Software Download, Management Reset,

 

 

Management Factory Reset

Power Status

A read-only field that indicates the current power source.

 

Default Value:

Primary Power

sysDescr

A read-only field that specifies the hardware and software version.

sysObjectID

A read-only field that provides a unique identification of the switch, which contains the

 

vendor’s private enterprise number.

sysUpTime

A read-only field that shows the length of time since the last reset. This field is

 

updated when the screen is redisplayed.

sysServices

A read-only field that indicates the switch’s physical and data link layer functionality.

sysContact

The name and phone number of the person responsible for the switch.

 

Default Value::

Zero-length string

 

Range:

Any ASCII string of up to 56 printable characters*

sysName

A name that uniquely identifies the switch.

 

Default Value::

Zero-length string

 

Range:

Any ASCII string of up to 56 printable characters*

sysLocation

The physical location of the switch.

 

Default Value:

Zero-length string

 

Range:

Any ASCII string of up to 56 printable characters

 

 

 

*Although this field can be set to up to 255 characters from a Network Management Station (NMS), only 56 characters are displayed on the console terminal.