BayStack 350 10/100/1000 Series Switches

In the configuration example shown in Figure 1-42 on page 1-62, the designated monitor port (port 23) can be set to monitor traffic in any of the following modes:

Monitor all traffic received by port X.

Monitor all traffic transmitted by port X.

Monitor all traffic received and transmitted by port X.

Monitor all traffic received by port X or transmitted by port Y.

Monitor all traffic received by port X (destined to port Y) and then transmitted by port Y.

Monitor all traffic received/transmitted by port X and received/transmitted by port Y (conversations between port X and port Y).

As shown in the Port Mirroring Configuration screen example (Figure 1-43), a user has designated port 23 as the Monitor Port for ports 24 and 25 in switch S1.

The Monitoring Mode field [ - > Port X or Port Y - > ] indicates that all traffic received by port X or all traffic transmitted by port Y is currently being monitored by the StackProbe attached to Monitor Port 23.

The screen data displayed at the bottom of the screen shows the currently active port mirroring configuration.

304376-B Rev 00

1-63

Page 87
Image 87
Nortel Networks manual BayStack 350 10/100/1000 Series Switches