Statements for SM2 administrators

REMOVE-COSMOS-EVENT

REMOVE-COSMOS-EVENT

Remove events from COSMOS monitoring parameters

Function

This statement is used to define events which are to be removed from the COSMOS monitoring program definition.

Format

REMOVE-COSMOS-EVENT

EVENT-NAME = *STANDARD-EVENTS / *ALL / list-poss(67): *STANDARD-EVENTS / *ACF / *BCAM / *BCPT / *BLS / *BOUR / *CHTM / *CMD / *CMS / *DAB / *DCAM / *DLM / *EIA / *EIA2 /

*EIA3 / *FITC / *GSAC / *HAL / *IDLE / *INTR / *IONQ / *ISEV / *ISPL / *KAI / *LOCK / *MSG / *NSM / *PAGE / *PAM / *PCCC / *PCTC / *PDEA / *PEND / *PIO / *PMIO / *PRGS / *PRGT /

*PRTY / *RELM / *REQM / *SDV / *SLOT / *SNAP / *STD1 / *STDI / *STDN / *SVC /

*TGMA / *TGMP / *TGMT / *TIC / *TINF / *TLM / *TLT / *TSKI / *TSVC / *UTM / *VMCH / *VMH / *VMI / *VMLK / *VMPD / *VMPR / *VMS / *VM2 / *WSCT / *XEIA

Operands

EVENT-NAME =

Specifies the names of the events to be removed from the monitoring program definition.

EVENT-NAME = *STANDARD-EVENTS

The following standard events are to be removed from the monitoring program definition: ACF, BLS, BOUR, CHTM, CMS, DAB, EIA2, EIA3, FITC, IDLE, INTR, IONQ, PAGE, PAM, PCCC, PCTC, PEND, PMIO, PRGS, PRGT, RELM, REQM, SDV, SVC, TSKI, TSVC, WSCT.

EVENT-NAME = *ALL

All events - except the mandatory events CREA, DEST, INIT, LGON, MMRC, PTSK and STAT - are removed from the monitoring program definition.

U3585-J-Z125-8-76

105

Page 105
Image 105
Siemens U3585-J-Z125-8-76 1 manual Remove-Cosmos-Event, Remove events from Cosmos monitoring parameters, Event-Name = *All