SM2 monitoring program

Operating modes/users

2.2 SM2 operating modes

SM2 offers three operating modes:

1.Real-time monitoring (information output to a data display terminal)

2.Background monitoring (information output to a file for subsequent analysis)

3.User-specific task monitoring

The operating modes can be used simultaneously.

When mode 1 is used, SM2 periodically outputs monitored data in the form of reports on the data terminal. The color version of the 9752 Data Display Terminal is supported. This data refers to the latest monitoring cycle (e.g. 150 seconds) and can be used as snapshots for assessing the current system status. Only selected SM2 monitored data is output in this mode.

When mode 2 is used, the collected data is output in the form records to a file, the SM2 output file. This data can be analyzed later using SM2 products. This mode allows for selective use of the SM2 operands and is equally suitable for long-term monitoring with a low system load and for brief special-purpose monitoring with a correspondingly higher system load.

When mode 3 is used, the nonprivileged user (using the START-TASK-MEASUREMENT command) can register tasks under his/her own ID for monitoring by SM2. In addition to the task-specific monitored data, a command counter and SVC task statistics can be requested. In the case of user-specific task monitoring, all information is written to user- specific SM2 output files.

U3585-J-Z125-8-76

11

Page 11
Image 11
Siemens U3585-J-Z125-8-76 1, SM2 monitoring system manual SM2 operating modes, Operating modes/users