ADD-CONNECTION-SET

Statements for SM2 administrators

Format

ADD-CONNECTION-SET

SET-NAME = <alphanum-name 1..16>

,SET-DEFINITION = *BY-CONNECTION / *EXCEPT-CONNECTION ,CONNECTION-SET = list-poss(5): *CONNECTION(...)

*CONNECTION(...)

APPLICATION = *ALL / <alphanum-name 1..8 with-wild>

,PARTNER = *ALL / <alphanum-name 1..8 with-wild>

,PROCESSOR = *ALL / <alphanum-name 1..8 with-wild> ,CONNECTION-TYPE = *REMOTE / *LOCAL / *BOTH

Operands

SET-NAME = <alphanum-name 1..16>

Defines a name for the selected connection set.

SET-DEFINITION =

Defines the connection set to be monitored.

SET-DEFINITION = *BY-CONNECTION

All connection groups defined in the connection set are monitored.

SET-DEFINITION = *EXCEPT-CONNECTION

All connection groups except those defined in the connection set are monitored.

CONNECTION-SET = list-poss(5): *CONNECTION(...)

Defines a selection of up to five connection groups.

APPLICATION = *ALL / <alphanum-name 1..8 with-wild> *ALL: No special application is selected.

<alphanum-name 1..8>: Specifies the name of the selected application. An asterisk (*) is also permitted as the last character in a wildcard specification.

PARTNER = *ALL / <alphanum-name 1..8 with-wild> *ALL: No special partner is selected.

<alphanum-name 1..8>: Specifies the name of the selected partner. An asterisk (*) is also permitted as the last character in a wildcard specification.

70