NPS0528

NPS0528 INVALID DEVICE DEFINITION SPECIFIED FOR DEVICE ’(&00)’

(B) Routing code: R Weight: 99

Meaning

When defining a monitoring program, an attempt was made to specify a device that is not valid for this program.

The statement has been rejected. Possible reasons:

-device is unknown

-device is not a disk

-device is not attached

-device is a GS volume

NPS0529 INVALID CHANNEL DEFINITION SPECIFIED FOR CHANNEL NUMBER ’(&00)’

(B) Routing code: R Weight: 99

Meaning

When defining a monitoring program, an attempt was made to specify an invalid channel number.

The statement has been rejected.

NPS0530 MONITORING PROGRAM ’(&00)’ INVALID DEFINED. STATEMENT REJECTED

Meaning

It was attempted to start a monitoring program with invalid devices.

Invalid devices are:

-Devices, which are not any more in the configuration

-Devices, which are not in the status ’ATTACHED’ (only for measurement program DISK)

-GS-Volumes

Response

Check and correct monitoring program definition.

NPS0531 WARNING: MONITORING PROGRAM ’(&00)’ PARTLY INVALIDLY DEFINED. INVALID DEVICES IGNORED

Meaning

While starting a monitoring program, it was found that some invalid devices were selected. The monitoring program is only started with the valid devices; the invalid devices are not monitored.

Invalid devices are:

-Devices, which are not any more in the configuration

-Devices, which are not in the status ’ATTACHED’ (only for measurement program DISK)

-GS-Volumes

U3585-J-Z125-8-76

381

Page 381
Image 381