Statements for SM2 administrators

ADD-BCAM-CONNECTION-SET

Operands

SET-NAME = <alphanum-name 1..16>

Defines a name for the selected connection set.

CONNECTION-SELECTION =

Defines the type of connection set to be monitored.

CONNECTION-SELECTION = *BY-NEA-NAME(...)

Defines a selection of connections in accordance with the application name.

CONNECTION-NAME = list-poss(16): *SPECIFIED(...)

LOCAL-APPLICATION = *ANY / <alphanum-name 1..8 with wild> *ANY: No special local application is selected.

<alphanum-name 1..8>: Specifies the name of the selected local application. An asterisk (*) is also permitted as the last character in a wildcard specification.

,PARTNER-APPLICATION = *ANY / <alphanum-name 1..8 with wild> *ANY: No special partner application is selected.

<alphanum-name 1..8>: Specifies the name of the selected partner application. An asterisk (*) is also permitted as the last character in a wildcard specification.

CONNECTION-SELECTION = *BY-PORT-NUMBER(...)

Defines a selection of connections in accordance with the port number.

PORT-NUMBER = list-poss(16): *SPECIFIED(...)

LOCAL-PORT-NUMBER = *ANY / <integer 1..65535> *ANY: No special local transport address is selected. <integer 1..65535>: Local transport address.

PARTNER-PORT-NUMBER = *ANY / <integer 1..65535> *ANY: No special partner transport address is selected. <integer 1..65535>: Partner transport address.

CONNECTION-TYPE =

Specifies the type of connection to be taken into consideration for the connection set.

CONNECTION-TYPE = *REMOTE

Only remote connections are taken into consideration.

CONNECTION-TYPE = *LOCAL

Only local connections are taken into consideration.

CONNECTION-TYPE = *BOTH

Both local and remote connections are taken into consideration.

U3585-J-Z125-8-76

67

Page 67
Image 67