Siemens SM2 monitoring system, U3585-J-Z125-8-76 1 manual Output, Define output mode

Models: SM2 monitoring system U3585-J-Z125-8-76 1

1 500
Download 500 pages 4.26 Kb
Page 166
Image 166

OUTPUT

Statements for nonprivileged users

OUTPUT

Define output mode

Function

This statement is used to:

define the device (data display terminal and/or printer) to which the reports are output, and

define the mode of output.

Reports are output either automatically at regular intervals (automatic output mode) or at the request of the user (controlled mode).

Format

Operation

Operands

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT

 

 

 

 

 

 

 

 

 

 

TERMINAL

Y[ES]

 

 

[

TER

=

 

 

 

]

 

 

N[O]

 

 

HARDCOPY

Y[ES]

 

[,

=

]

 

HC

 

N[O]

 

 

INTERVAL

[number]

 

[,

INT

=

 

 

 

 

]

 

C[ONTROLLED]

 

 

 

 

 

 

 

 

 

 

Operands

TERMINAL

 

=YES

Directs output of the reports to the data display terminal (default).

=NO

Deactivates report output to the data display terminal.

HARDCOPY

 

=YES

Directs output of the reports to the system file SYSLST.

 

If SM2 runs in batch mode, the reports are always output to

 

SYSLST.

=NO

Prevents output of the report to the system file SYSLST (default).

166

U3585-J-Z125-8-76

Page 166
Image 166