SM2 information screens

ACTIVE PARAMETER

5.2 SM2 information screens

ACTIVE PARAMETER

This screen displays the parameters set for the active monitoring programs. As many screens as are necessary are output. If sufficient space is available, all the parameters for one monitoring program are displayed on a single screen. It is only possible to request output from the administration section using the SHOW-ACTIVE-PARAMETER statement.

D016ZE04 SM2 ACTIVE PARAMETER

 

 

 

99-03-24

14:20:59

BCAM CONNECTION PARAMETER

 

 

 

 

 

-------------------------

 

 

 

 

 

INWAIT-BUCKETS

: 5, 10, 100, 1000

 

 

 

 

REACT-BUCKETS

: 500, 1000, 2000, 4000

 

 

 

INPROC-BUCKETS

: 5, 10, 100, 1000

 

 

 

 

OUTPROC-BUCKETS

: 5, 10, 100, 1000

 

 

 

 

BCAM CONNECTION SET

 

 

 

 

 

 

SET-NAME

 

: DIALOG

 

 

PORT1110

 

CONNECTION-TYPE

: REMOTE

 

 

REMOTE

 

HOST-SELECTION

:

 

 

 

 

 

(LOCAL

/ PARTNER )

(*ANY

/ *ANY

)

(*ANY

/ *ANY

)

CONNECTION-SELECTION

: *BY-NEA-NAME

 

*BY-PORT-NUMBER

 

(LOCAL

/ PARTNER

) ($DIALOG

/ *ANY

)

(

1110 / *ANY

)

CHANNEL-IO PARAMETER

 

 

 

 

 

 

--------------------

 

 

 

 

 

 

CHANNELS

 

: *ALL

 

 

 

 

 

 

 

 

 

 

 

 

 

Monitoring information

BCAM-CONNECTION-PARAMETER

INWAIT-BUCKETS

Definition of the upper limits of up to four ranges in which the

 

INWAIT times are listed by order of magnitude

REACT-BUCKETS

Definition of the upper limits of up to four ranges in which the

 

REACT times are listed by order of magnitude

INPROC-BUCKETS

Definition of the upper limits of up to four ranges in which the

 

INPROC times are listed by order of magnitude

OUTPROC-

 

BUCKETS

Definition of the upper limits of up to four ranges in which the

 

OUTPROC times are listed by order of magnitude

U3585-J-Z125-8-76

319

Page 319
Image 319
Siemens U3585-J-Z125-8-76 1, SM2 monitoring system manual SM2 information screens, Active Parameter