SET-BCAM-CONNECTION-PARAMETER

Statements for SM2 administrators

SET-BCAM-CONNECTION-PARAMETER

Define BCAM-CONNECTION monitoring parameters

Function

This statement is used to define the global monitoring parameters for the

BCAM-CONNECTION monitoring program.

Format

SET-BCAM-CONNECTION-PARAMETER

INWAIT-BUCKETS = *STD-LIMITS / *UNCHANGED / list-poss(4):<integer 1..999999> ,REACT-BUCKETS = *STD-LIMITS / *UNCHANGED / list-poss(4):<integer 1..999999> ,INPROC-BUCKETS = *STD-LIMITS / *UNCHANGED / list-poss(4):<integer 1..999999> ,OUTPROC-BUCKETS = *STD-LIMITS / *UNCHANGED / list-poss(4):<integer 1..999999>

Operands

INWAIT-BUCKETS =

Defines the upper limits of up to four ranges (in units of 1 ms) in which the INWAIT times are to be stored by order of magnitude.

INWAIT-BUCKETS = *STD-LIMITS

Sets the upper limits of the ranges for INWAIT times to 100, 200, 500 and 1000 ms.

INWAIT-BUCKETS = *UNCHANGED

The upper limits of the ranges for INWAIT times currently defined in BCAM are not changed.

INWAIT-BUCKETS = list-poss(4): <integer 1..999999>

Defines the upper limits of the ranges for INWAIT times. These must be specified in ascending order.

REACT-BUCKETS =

Defines the upper limits of up to four ranges (in units of 1 ms) in which the REACT times are to be stored by order of magnitude.

REACT-BUCKETS = *STD-LIMITS

Sets the upper limits of the ranges for REACT times to 500, 1000, 2000 and 4000.

REACT-BUCKETS = *UNCHANGED

The upper limits of the ranges for REACT times currently defined in BCAM are not changed.

112

U3585-J-Z125-8-76

Page 112
Image 112
Siemens SM2 monitoring system manual Set-Bcam-Connection-Parameter, Define BCAM-CONNECTION monitoring parameters