Siemens SM2 monitoring system, U3585-J-Z125-8-76 1 manual NPS0521 Messages, Buffer-Length

Models: SM2 monitoring system U3585-J-Z125-8-76 1

1 500
Download 500 pages 4.26 Kb
Page 380
Image 380

NPS0521

Messages

NPS0521 ONLY ’BUFFER-LENGTH=*STD(SIZE=16)’ PERMITTED FOR SM2 LOGGING FILE. STATEMENT REJECTED

Meaning

SM2 logging files are only permitted with ’BUFFER-LENGTH=*STD(16)’.

The value of the BUFFER-LENGTH operand in the /ADD-FILE-LINK command for a non- standard SM2 logging file is invalid or the existing non-standard SM2 logging file has wrong

BUFFER-LENGTH.

Response

Retry the /ADD-FILE-LIND command without the BUFFER-LENGTH operand and then retry OPEN-LOG-FILE statement.

If you want to open extend a non-standard SM2 logging file of an older SM2 version, you first have to convert the file with SM2U1.

NPS0522 SM2 LOGGING FILE NOT OPENED. STATEMENT REJECTED

(B) Routing code: R Weight: 99

Meaning

An attempt was made to start a monitoring program while the SM2 logging file was not opened.

NPS0523 MONITORING PROGRAM ’(&00)’ NOT DEFINED. STATEMENT REJECTED

(B) Routing code: R Weight: 99

Meaning

An attempt was made to start a non-defined monitoring program.

NPS0524 MONITORING PROGRAM ’(&00)’ ALREADY ACTIVE. STATEMENT REJECTED

(B) Routing code: R Weight: 50

Meaning

An attempt was made to start a monitoring program that has already been started.

NPS0526 TSN ’(&00)’ NOT IN SYSTEM. STATEMENT REJECTED

(B) Routing code: R Weight: 99

Meaning

An attempt was made to start a monitoring program for task statistics by specifying a TSN, but the corresponding task could not be found in the system at the time.

NPS0527 SYNTAX ERROR. UNKNOWN MONITORING PROGRAM SPECIFIED

(B) Routing code: R Weight: 99

Meaning

The statement has been rejected.

380

U3585-J-Z125-8-76

Page 380
Image 380
Siemens SM2 monitoring system, U3585-J-Z125-8-76 1 manual NPS0521 Messages, Buffer-Length