SM2 information screens

STATUS TABLE

STATUS TABLE

No monitoring data is output in the STATUS TABLE.

Output to the terminal comprises two parts. The first part provides the user with information on which SM2 tasks exist and on the status of the subsystems used by SM2. The line containing "MISSED RECORDS" is only output if unwritten records exist.

The second part outputs as many of the most recent trace entries as can be accommodated on one screen.

The SHOW-SM2-STATUS statement is used to request the output of the STATUS TABLE. This statement is only available to privileged users in the administration facility.

 

D016ZE07

SM2 STATUS TABLE

 

 

 

 

 

99-03-24 19:02:55

 

 

TASK / SS

 

 

START

TIME

 

STATUS

 

END TIME

 

 

GATHERER

 

1999-03-24

07:25:00

 

RUNNING

 

 

 

 

WRITE-TASK

1999-03-24

07:25:07

 

RUNNING

 

 

 

 

USER-WRITE-TASK

1999-03-24

07:25:18

 

RUNNING

 

 

 

 

BCAM-SM2

 

1999-03-24

07:25:19

 

IN USE

 

 

 

 

MSCF

 

1999-03-24

07:25:19

 

IN USE

 

 

 

 

DLM

 

1999-03-24

07:25:19

 

IN USE

 

 

 

 

NSM

 

1999-03-24

07:25:19

 

IN USE

 

 

 

 

LAST TRACED EVENTS

 

 

 

 

 

 

 

 

 

CUR#

TIME

TSN

REASON

TYPE

MODUL

ID

CODE

 

 

 

 

 

 

 

 

 

 

 

8

07:25:19

SM2G

NSM-STA

SS

NSM

0000

00000000

 

7

07:25:19

SM2G

DLM-STA

SS

DLM

0100

00000000

 

6

07:25:19

SM2G

MSC-STA

SS

MSCF

0100

00000000

 

5

07:25:19

SM2G

BCM-STA

SS

DSSM

0000

00000000

 

4

07:25:18

SM2U

CREATE

TASK

UDM

0000

00000000

 

3

07:25:07

SM2W

CREATE

TASK

GDM

0000

00000000

 

2

07:25:00

SM2G

CREATE

TASK

GAT4

0000

00000000

 

 

 

 

 

 

 

 

 

 

 

 

Monitoring information

TASK / SS

Name of the task or subsystem

START TIME

Date (in ISO4 format) and time at which the task or subsystem was

 

created

STATUS

Status of the task or subsystem