PCS report

SM2 reports

PCS report

This report provides an overview of the activities of the Performance Control Subsystem.

Report output

The REPORT PCS statement is used to request the output of the PCS report. The report can only be output if PCS was active during the last monitoring cycle.

 

D016ZE04 SM2 PCS

CYCLE:

120 S

SAMPLES:

 

293

 

99-03-24

14:30:00

 

 

 

 

 

 

 

 

 

CATEGORY

SRACT (1/SEC)

SQPLN

SQACT

RDACT

DUR-RO DUR-RO-P

 

 

NAME

TOTAL

IO

CPU

(%)

(%)

 

(1/SEC) (1/SEC)

 

 

+---------

+

-------+

-------+-------

+

-------

+

-------

+

--------

+

--------

+

--------

+

 

 

SUM

42739

5765

30845

 

100.0

1.0

0.657

0.000

 

 

SYS

5442

1659

3688

0.0

12.7

1.0

0.000

0.000

 

 

DIALOG

57

0

57

1.0

0.1

1.2

0.000

0.000

 

 

BATCH

520

29

472

2.3

1.2

1.1

0.000

0.000

 

 

TP

447

8

392

5.1

1.0

1.6

0.000

0.000

 

 

TP1

63

4

55

21.2

0.1

1.0

0.000

0.000

 

 

BATCHDB

0

0

0

11.7

0.0

**

0.000

0.000

 

 

BATCHF

818

720

94

1.1

1.9

1.0

0.000

0.000

 

 

DIALOG1

12227

2352

7888

20.7

28.6

1.0

0.491

0.000

 

 

DIALOG2

7002

564

5395

20.0

16.3

1.0

0.166

0.000

 

 

DIALOG3

16163

429

12805

16.4

37.8

1.1

0.000

0.000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Monitoring information

This report contains the totals (SUM column) for all categories (except for the SQPLN and RDACT values) in the first line below the table header. The data for the individual categories (up to 16) is output in the following lines.

CATEGORY NAME

Name of a category

SRACT (1/SEC)

Service rate used by this category, specified as TOTAL, IO and CPU

TOTAL

Total number of all service rates used by this category (sum of IO,

 

CPU and memory service rates)

IO

IO service rates used by this category

CPU

CPU service rates used by this category

280

U3585-J-Z125-8-76

Page 280
Image 280
Siemens SM2 monitoring system, U3585-J-Z125-8-76 1 manual PCS report SM2 reports, Sract 1/SEC, Cpu