Siemens U3585-J-Z125-8-76 1, SM2 monitoring system manual Examples of monitoring program definitions

Models: SM2 monitoring system U3585-J-Z125-8-76 1

1 500
Download 500 pages 4.26 Kb
Page 37
Image 37

SM2 monitoring programs

BCAM-CONNECTION

Examples of monitoring program definitions

Example 1

SET-BCAM-CONNECTION-PARAMETER

INWAIT-BUCKETS = *UNCHANGED,

REACT-BUCKETS = *UNCHANGED,

INPROC-BUCKETS = *UNCHANGED,

OUTPROC-BUCKETS = *UNCHANGED

ADD-BCAM-CONNECTION-SET

SET-NAME = setname1,

CONNECTION-SELECTION = *BY-NEA-NAME (

CONNECTION-NAME = *SPECIFIED (

LOCAL-APPLICATION = $DIALOG,

PARTNER-APPLICATION = *ANY)),

CONNECTION-TYPE = *REMOTE,

HOST-SELECTION = *SPECIFIED (

LOCAL-HOST-NAME = *LOCAL,

PARTNER-HOST-NAME = hostname1)

START-MEASUREMENT-PROGRAM TYPE = *BCAM-CONNECTION

In these statements, the monitoring parameters set in BCAM are transferred. A connection set is defined which records all connections with the name type NEA and the local appli- cation name $DIALOG. The connections are remote and lead to the specified hosts.

U3585-J-Z125-8-76

37

Page 37
Image 37
Siemens U3585-J-Z125-8-76 1, SM2 monitoring system manual Examples of monitoring program definitions