Statements for SM2 administrators

ADD-CONNECTION-SET

ADD-CONNECTION-SET

Add connection set for RESPONSETIME monitoring

Function

This statement is used to define a connection set which is to be added to the RESPONSETIME monitoring program definition. A connection set consists of one or more (as many as five) connection groups. The connection set can be either positively defined (i.e. all groups specified in this connection set are monitored) or negatively defined (i.e. all groups except those specified in the connection set are monitored). For each connection set, a freely selectable name must be assigned; the name is the one under which this set can be addressed in the REMOVE-CONNECTION-SET statement and also addressed by SM2R1 for analysis purposes. If a connection set is defined, it is also possible to specify whether remote, local or both types of connections are to be taken into account for the set. SM2 then passes the correct parameter value to BCAM-SM2. This value then applies to this connection set only.

This statement cannot be entered until after the SET-RESPONSETIME-PARAMETER statement has been entered. The SET-RESPONSETIME-PARAMETER statement automatically defines a connection set with the name *GLOBAL in which all connections are monitored (*CONNECTION (*ALL,*ALL,*ALL)). The value CONNECTION-TYPE= *REMOTE applies for this connection set and cannot be changed.

A total of 16 connection sets (*GLOBAL inclusions) may be defined with a total of 16 different connection groups ((*ALL,*ALL,*ALL) inclusion). If this number is exceeded, the statement will be rejected and a message to this effect issued. If an attempt is made to declare more than one set under one set name, the statement will be rejected and a message will be issued.

U3585-J-Z125-8-76

69

Page 69
Image 69
Siemens U3585-J-Z125-8-76 1, SM2 monitoring system manual Add-Connection-Set, Add connection set for Responsetime monitoring