Sample procedures

Notes on SM2 operation

SET-RESPONSETIME-PARAMETER

 

 

ADD-CONNECTION-SET SET-NAME=CONN1,SET-DEFINITION=*BY-CONNECTION,

-

CONNECTION-SET=*CONNECTION(APPLICATION=$DIALOG,PARTNER=*ALL,

-

PROCESSOR=*ALL)

 

 

ADD-CONNECTION-SET SET-NAME=CONN2,SET-DEFINITION=*BY-CONNECTION,

-

CONNECTION-SET=*CONNECTION(APPLICATION=UTM1,PARTNER=*ALL,

-

PROCESSOR=*ALL)

 

REMARK

=============================================================

REMARK

****

OPEN SM2 FILE, SPECIFY MONITORING CYCLE AND

****

REMARK

****

SAMPLING CYCLE

****

REMARK

=============================================================

MODIFY-MEASUREMENT-PERIODS OFFLINE-PERIOD=&CYCLE,SAMPLING-PERIOD=&SAMPLE OPEN-LOG-FILE FILE=*BY-LINK-NAME

REMARK =============================================================

REMARK **** START MONITORING PROGRAMS****

REMARK =============================================================

START-MEASUREMENT-PROGRAM TYPE=(*SYSSTAT,*TASK,*DISK,*FILE,*RESPONSETIME)

REMARK

=============================================================

REMARK

****

TERMINATE SM2 USER PROGRAM

****

REMARK

****

MONITORING CONTINUES IN THE BACKGROUND !!!

****

REMARK

=============================================================

END

/END-PROCEDURE