ADD-ISAM-POOL - Define ISAM pool to be monitored

POOL-NAME = <alphanum-name 1..8>

,SCOPE = *HOST-SYSTEM / *TASK(...) / *USER(...)

*TASK(...)

TSN = <alphanum-name 1..4> *USER(...)

USER-ID = <alphanum-name 1..8> ,CAT-ID = *HOME-PVS / <catid 1..4>

CALL-ADMINISTRATION-PART - Switch from evaluation part to administration facility

CALL-EVALUATION-PART - Switch from administration facility to evaluation part

CHANGE-MEASUREMENT-PROGRAM - Stop current monitoring program run and restart it with new monitored objects/monitoring parameters

TYPE = list-poss(12): *BCAM-CONNECTION / *CHANNEL-IO / *COSMOS / *DISK / *DISK-FILE / *FILE / *ISAM / *PERIODIC-TASK / *RESPONSETIME / *SERVICETIME / *SYSSTAT / *TASK

CLOSE-LOG-FILE - Close SM2 output file