MEMORY report

SM2 reports

D016ZE04 SM2 MEMORY

(SYS)

CYCLE:

120 S

SAMPLES:

293

 

99-03-24

14:30:00

 

MAIN MEMORY FRAMES

 

 

 

 

 

WORK. SET (PPC)

+--------

+---------

+--------

+--------

+----------

+----------

+

+-------

+

-------+

TOTAL

PAGEABLE

R-ONLY-QRD-WR-Q

SYS-GLOB

TASK-LOC

ALL

ACT

+--------

+---------

+--------

+--------

+----------

+----------

+

+-------

+

-------+

499713

480617

37969

56452

386164

0

53579

8915

+--------

+---------

+--------

+--------

+----------

+----------

+

+-------

+

-------+

PAGING AREA FRAMES

 

+--------

+

--------+--------

+

TOTAL

GS USED

+--------

+

--------+--------

+

1536363

0 692412

+--------

+

--------+--------

+

 

# PAGES IN

VIRTUAL MEMORY

 

+

-----+-----

+

-----+-----

+-----

+

CL1 CL2

CL3 CL4 CL4-S

+

-----+-----

+

-----+-----

+-----

+

721 20761453332301 584

+-----

+-----

+-----

+-----

+-----

+

 

USED PAGES

+

----------+

ACT

+

----------+

62377

+

----------+

 

PAGE FAULTS

 

 

PAGE TRANSFERS

 

PAGE TRANSFERS (GS)

 

+--------

+----------

+

---------+ +

----------

+

----------

+ +

----------

+

----------

+

TOTAL

1ST-READ

RECLAIMS

READ

WRITE

READ

WRITE

+--------

+----------

+

---------+ +

----------

+

----------

+ +

----------

+

----------

+

1168.9

1157.2

11.6

0.0

0.0

0.0

0.0

+--------

+----------

+

---------+ +

----------

+

----------

+ +

----------

+

----------

+

Monitoring information

PAGE FAULTS

 

TOTAL

Number of page fault interrupts per second (without "genuine"

 

paging errors)

1ST-READ

Number of page fault interrupts per second caused by the first

 

access to a 4-Kb page

RECLAIMS

Number of page fault interrupts per second for which the addressed

 

4-Kb page is still in main memory

Note

The TOTAL value also contains the number of page fault interrupts leading to transfer from/to global storage, if any.