SM2 monitored variables

SM2 monitoring program

2.9 SM2 monitored variables

The table below shows the main monitored variables of SM2.

A table showing the links between the monitored variables and monitoring programs, ONLINE reports, and SM2R1 report groups can be found in chapter “Variables reports” on page 361.

Monitored variable

Description

 

 

Cache

 

 

 

Access statistics and hit rates for

Number of read/write accesses to DAB cache areas per second

DAB caches

and the percentage frequency of read/write accesses to DAB

 

subareas without disk access.

Access statistics for ISAM pools

Number of ISAM accesses per second to pages in the ISAM

 

pool and directly to disk, as well as the number of ISAM

 

accesses with a delay per second.

 

Size of the ISAM pool, reserved pages and fixed pages in PAM

 

pages.

Access statistics and hit rates for

Number of read/write accesses to PCA or DAB cache areas per

hiperfiles (PFA)

second, and their percentage share of the total number of read/

 

write accesses.

 

Number of failed attempts to use the cache per second.

Access statistics and hit rates for

Number of read/write accesses to SYMMETRIX controllers and

SYMMETRIX controllers

devices.

 

Proportion of read/write accesses handled successfully by the

 

cache.

Access statistics and hit rates for

Number of read/write accesses and their percentage share of

controllers with cache (PCA)

the total number of read/write accesses for PCA controllers,

 

cache areas, and devices.

 

 

CPU

 

 

 

CPU utilization

Time during which the processor is in one of the following

 

statuses: TU, TPR, SIH, IDLE or STOP.

 

In SR2000 systems, /390 time will also be output.

Number of system calls

Number of SVC calls in TU/TPR per second, and the sum of all

 

SVC calls per second.

 

 

Files

 

 

 

Catalog access statistics

Number of read/write accesses to catalog entries/JV entries of

 

files per second, as well as average access times in milli-

 

seconds.

 

 

Table 2: SM2 monitored variables

 

20

U3585-J-Z125-8-76

Page 20
Image 20
Siemens SM2 monitoring system manual SM2 monitored variables SM2 monitoring program, Monitored variable Description